ROOM CO2 SENSORS
TYPICAL APPLICATIONS (but not limited to):
Demand-controlled ventilation (DCV)
IAQ monitoring
Occupancy-based ventilation control
BAS CO₂ feedback
Conference rooms and classrooms
Commercial building ventilation optimization
ROOM CO2 SENSOR
WITH OR WITHOUT LED INDICATOR
OVERVIEW
High quality room carbon dioxide (CO2) sensor with optional temperature sensor in an attractive low-profile plastic enclosure. These room sensors are available as a CO2 only or as a combination sensor or with CO2/RH/temperature measurements. CO2 and CO2+T options are also available with status indicator LED.
Available with preset onboard DIP switches that enable user to select analog output signal of 0-5V, 0-10V and 4-20mA for CO2 sensing. Digital outputs also available on request. Accurate CO2 measurement from 400-10,000 ppm CO2.
Dual channel sensing technology and a solid state infrared source ensures long lifetime, excellent accuracy and repeatability with low drift and quick start up.
FEATURES
CO2 or CO2/Temp options
Attractive, streamlined, low-profile ABS enclosure
Quick Connect wire terminals
NTC thermistors and RTD temperature elements available
Dual beam infrared sensing technology (NDIR)
CO2 measurement in 0-5V, 0-10V or 4-20mA analog outputs (selectable)
CO2 ranges 0-2000 ppm, 0-5000 ppm or 0-10,000 ppm measurement
Optional status indicator LED
Insulated back included
5 year limited warranty
Made in the USA
INSTRUCTIONS
AERO COMBO SENSOR
CO2, HUMIDITY & TEMPERATURE
OVERVIEW
High quality room CO2 sensor and/or CO2 with Relative Humidity and passive temperature sensor in an attractive low-profile plastic enclosure.
Dual channel technology and a solid state infrared source ensures long lifetime, excellent accuracy and repeatability with low drift and very fast start up. Very accurate CO2 measurement from 400-10,000 ppm (CO2) and 0-100% (RH) with 2% accuracy.
Standard versions complete with on board DIP switches that provide output signal change in the field for 0-5V, 0-10V and 4-20mA.
Fixed analog outputs or digital BACnet or MODBUS are also available for custom orders.
FEATURES
CO2 or Combination CO2/RH/Temp options
Dual beam infrared sensing technology (NDIR)
Quick Connect wire terminals
Passive NTC thermistors and RTD elements available
Standard Analog Output Signals 0-5V, 0-10V, 4-20mA for both CO2 and in CO2/RH combo options
Digital MODBUS output available for custom orders
0-2000 ppm, 0-5000 ppm or 0-10,000 ppm measurement range
Low profile ABS housing with Insulated back
CE & RoHS compliant
5 year limited warranty
Made in the USA